Boiler V3 - steel without feeder

V3

Description

V3 boiler is a boiler steel, universal adapted to the upper and lower lighting. It has a plate heat exchanger, vertical in the trigeminal system, made ​​of steel sheets P265GH 6 mm thick. The used water grate increases the area of ​​heating and heat removal. Water body is covered with a thermal insulation made ​​of mineral wool, steel plates covered with a jacket. The combustion process can be adjusted manually using the adjusting screw located in the lower door of the air damper or by air draft regulator (temperature regulator is not standard equipment of the boiler ). The boiler can also be equipped with a ventilation unit and a microprocessor controller that controls the combustion process, adjusting the air flow and maintaining the desired temperature of water (optional - charge ).

Boilers V-3 have the upper washout hole through which the access to tapes exchanger and cleanout bottom on both sides of the boiler.

The main advantage is the possibility of the two-mode boiler operation which enables the use of solid fuels most:
- Lower firing, coal, wood, briquette, it is also the use of blends of fuels such as coal, wood, pellets and fuel mixtures and biomass components, etc.
- Firing up the upper, coal had KL27/100 assortment, blend coal 31.2, Class 27/9, assortment walnut II ( OII ) and the assortment had MI.

There is also a version of the V -3 boilers designed for boiler lateral dimensions prevent the placement of V -3 in the basic version.

The boiler heating system works with the type of gravity or forced circulation made ​​in an open system and having safeguards that comply with standards PN-91/B-02413.

On our boilers 5 year warranty. Used electronics (controller + fan ) are covered by a 2-year warranty period.

Parametr Jednostka 18 24 30 34 38 45 50
Range of nominal power kW 4-18 6-24 8-30 10,2-34 11,4-38 13,5-45 15-50
Heating surface m2 2 2,6 3,2 3,4 3,8 4,5 4,9
Size of heated area m2 do 180 100-240 140-300 160-340 180-380 250-450 300-500
Thermal efficiency (optimal) % >81 >81 >81 >81 >81 >81 >81
The maximum allowable working pressure Mpa 0,15 0,15 0,15 0,15 0,15 0,15 0,15
Required string exhaust Pa 26 28 30 32 34 36 38
The recommended heating water c 55-90 55-90 55-90 55-90 55-90 55-90 55-90
chimney section cm2 250 250 280 300 320 350 350
chimney section cm x cm - - - - - - -
chimney section Ø mm - - - - - - -
Minimum height of chimney m 8 8 9 9 9 10 10
Dimensions of flue mm 180 180 180 180 180 180 220
Power V/Hz 230/50 230/50 230/50 230/50 230/50 230/50 230/50
diameter supply and return mm G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2"
boiler weight kg 330 360 390 400 430 480 540
Water storage capacity l 75 83 90 98 110 124 130
Capacity loading chamber l 36 43 50 60 72 95 115
height mm 1150 1150 1150 1150 1150 1250 1250
The height from the base to the axis of the flue mm 875 875 875 940 940 1050 1050
length mm 1145 1145 1115 1215 1215 1405 1405
width mm 500 550 600 650 700 750 800
Width of basket mm - - - - - - -
The depth of the combustion chamber mm 390 390 390 390 390 490 490

* Surface Oriental dependent on climatic conditions, building insulation, heat demand, etc.
** The height of the boiler is given without a fan. If you mount the fan M PLUS M WPA type 120 should be added to the dimension of 180 mm.

 

MCE reserves the right to change without notice technical parameters, dimensions and specifications of the goods offered. Contained on this website information does not constitute assurance within the meaning of Art. 4 paragraph. 3 and 4 of the Act of 27 July 2002 on special conditions of consumer sale and amending the Civil Code (the "Act"), and do not constitute a description of the goods within the meaning of Art. 4 paragraph. 2 of the Act. This website does not constitute an offer within the meaning of Art. 66 of the Civil Code.