Description
V5 is cast iron, consisting of segments of the boiler, with water grate. High-quality cast iron heat exchanger wall thickness up to 8 mm for maximum corrosion resistance and longevity of the boiler.
V5 boilers are designed to burn solid fuels such as coal, coal dust, fleets, coke, wood, a mixture of coal, sawdust and wood chips. A wide range of fuels is distinguished from the rest of cast iron boilers. In the boiler flue V5 was used equipped with a stop over. The combustion process can be controlled manually or by using the draft regulator. The boiler can also be equipped with an air blower and a microprocessor controller that controls the combustion process, adjusting the air flow and maintaining the desired temperature of water at and hot water. The regulator and blower are set boiler accessories (optional payment).
The modular design of the heat exchanger provides a wide range of power and the ability to modify by increasing or decreasing the boiler in any period of operation. These boilers can be installed in open systems with gravity or forced circulation.
On our boilers receive a 10 year warranty. Used electronics (controller + fan ) are covered by a 2-year warranty period.
Parametr | Jednostka | 12 | 20 | 26 | 32 | 36 | 40 |
---|---|---|---|---|---|---|---|
Range of nominal power | kW | 12 | 20 | 26 | 32 | 36 | 40 |
Heating surface | m2 | - | - | - | - | - | - |
Size of heated area | m2 | do 90 | do 160 | do 220 | do 240 | do 290 | do 340 |
Thermal efficiency (optimal) | % | - | - | - | - | - | - |
The maximum allowable working pressure | Mpa | 0,4 | 0,4 | 0,4 | 0,4 | 0,4 | 0,4 |
Required string exhaust | Pa | - | - | - | - | - | - |
The recommended heating water | c | 60-85 | 60-85 | 60-85 | 60-85 | 60-85 | 60-85 |
chimney section | cm2 | - | - | - | - | - | - |
chimney section | cm x cm | - | - | - | - | - | - |
chimney section | Ø mm | - | - | - | - | - | - |
Minimum height of chimney | m | - | - | - | - | - | - |
Dimensions of flue | mm | 150 | 150 | 150 | 150 | 150 | 150 |
Power | V/Hz | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 | 230/50 |
diameter supply and return | mm | - | - | - | - | - | - |
boiler weight | kg | 175 | 210 | 245 | 280 | 315 | 350 |
Water storage capacity | l | 23 | 27 | 31 | 35 | 39 | 43 |
Capacity loading chamber | l | 17 | 25,5 | 34 | 42,5 | 51 | 59,5 |
height | mm | 1025 | 1025 | 1025 | 1025 | 1025 | 1025 |
The height from the base to the axis of the flue | mm | - | - | - | - | - | - |
length | mm | 640 | 740 | 840 | 940 | 1040 | 1140 |
width | mm | 500 | 500 | 500 | 500 | 500 | 500 |
Width of basket | mm | - | - | - | - | - | - |
The depth of the combustion chamber | mm | - | - | - | - | - | - |
tel. 33 872 24 04
tel/fax 33 873 25 11
tel/kom. +48 512 318 999
service: +48 509 810 955
mce@mce.net.pl