Description
Boiler V6 is a modern, twenty-four seven and fully automatic heating device. Optimal design of welded in the shape of a cuboid of three section, vertical- combustion chambers for high efficiency and longevity of the boiler at the same time. Plate heat exchanger is made of steel sheets P265GH 6 mm thick. Water body is covered with a thermal insulation of mineral wool skirt built- plates. Boiler V6 is equipped with a high quality automatic fuel feeder and microprocessor control. Controlling the combustion process by administering to the hearth cast iron retort optimum amount of fuel and air required for highly efficient combustion means that the device is one of the cheapest in operation.
The primary fuel is a " crumb " that coal type 31.2 with size from 5 to 25 mm. The set also includes a replacement grate allows the burning of wood, coal, coal ( different grain size ) and a number of other solid fuels.
V6 boilers have washout from the top, from which access to the shelves is water and the cleaning hole in the lower part of both sides of the boiler.
We also perform the boilers of the individual order for an additional charge:
- installation of rotary feeder - burning pulverized coal , oats, pellets.
- installation of the driver supports 4 pumps (which , hot water , floor , circulation ) and four- valve actuator. Additionally, it can be connected to a room thermostat.
- can be made larger hopper .
V6 boiler heating system works with the type of gravity or forced circulation made in an open system and having safeguards that comply with standards PN-91/B-02413.
On our boilers 5 year warranty. Used electronics (controller + fan ) and the fuel delivery system are covered by a 2-year warranty period.
Parametr | Jednostka | 25 | 32 | 42 | 50 |
---|---|---|---|---|---|
Range of nominal power | kW | 8-25 | 10-32 | 12-42 | 15-50 |
Heating surface | m2 | 2,85 | 3,65 | 4,3 | 5,25 |
Size of heated area | m2 | 60-250 | 100-320 | 120-420 | 120-500 |
Thermal efficiency (optimal) | % | >89 | >89 | >89 | >89 |
The maximum allowable working pressure | Mpa | 0,15 | 0,15 | 0,15 | 0,15 |
Required string exhaust | Pa | 22 | 23 | 26 | 26 |
The recommended heating water | c | 60/85 | 60/85 | 60/85 | 60/85 |
chimney section | cm2 | 280 | 280 | 320 | 320 |
chimney section | cm x cm | - | - | - | - |
chimney section | Ø mm | - | - | - | - |
Minimum height of chimney | m | 8 | 9 | 10 | 10 |
Dimensions of flue | mm | 180 | 180 | 220 | 220 |
Power | V/Hz | 230V/50Hz | 230V/50Hz | 230V/50Hz | 230V/50Hz |
diameter supply and return | mm | G 1 1/2'' | G 1 1/2'' | G 1 1/2'' | G 2'' |
boiler weight | kg | 480 | 550 | 620 | 710 |
Water storage capacity | l | 85 | 120 | 158 | 188 |
Capacity loading chamber | l | - | - | - | - |
height | mm | 1350 | 1350 | 1600 | 1600 |
The height from the base to the axis of the flue | mm | - | - | - | - |
length | mm | 1060 | 1060 | 1220 | 1220 |
width | mm | 500 | 580 | 670 | 720 |
Width of basket | mm | 1150 | 1180 | 1300 | 1320 |
The depth of the combustion chamber | mm | - | - | - | - |
MCE reserves the right to change without notice technical parameters, dimensions and specifications of the goods offered. Contained on this website information does not constitute assurance within the meaning of Art. 4 paragraph. 3 and 4 of the Act of 27 July 2002 on special conditions of consumer sale and amending the Civil Code (the "Act"), and do not constitute a description of the goods within the meaning of Art. 4 paragraph. 2 of the Act. This website does not constitute an offer within the meaning of Art. 66 of the Civil Code.
tel. 33 872 24 04
tel/fax 33 873 25 11
tel/kom. +48 512 318 999
service: +48 509 810 955
mce@mce.net.pl