PL EN RU

Boiler V2 - steel without feeder

V2

Description

Boilers V2 are recommended for users looking for a cheap and efficient source of heat. They are produced in two versions:

Boiler V2 S is adapted for dual-mode operation:
- The upper combustion : coal assortment KL27/100 had a moisture content of approximately 30 %, a mixture of coal 31.2, Class 27/9, assortment walnut II ( OII ) and the assortment had MI with a calorific value min. 27 MJ / kg. Humidity these fuels should not exceed 10%.
 - Lower combustion: coal, wood, briquette. It is also possible mixtures of fuels such as coal, wood, pellets and fuel mixtures and biomass components, etc. As a substitute fuels can be used: brown coal, briquettes from coal or lignite, wood , etc.
 The boiler is fitted as standard with a fan and a microprocessor controller that controls the combustion process by regulating the air flow and maintaining the desired temperature of water at and hot tap water. The controller allows connecting pump and DHW.

Boiler V2 is a versatile low- incinerating furnace adapted for combustion of solid fuels - coal, wood, briquett , it is also the use of blends of fuels (coal + had ) V2 etc. The boiler is factory fitted for a set of draft regulator or blow in a very easy way.

The design of the boilers V2 provides maximum heat removal from the flue gas and the corresponding slope of the chambers inside the heat exchanger results in a smoother flow of (efficiency up to 81 %).

Boilers, heating installation work with the type of gravitational or forced circulation made ​​in an open system and having safeguards that comply with standards PN-91/B-02413.

On our boilers give 4 year warranty. Used electronics (controller + fan ) are covered by a 2-year warranty period.

Parametr Jednostka 12 15 20 25 30 38 45
Range of nominal power kW 4-12 8-15 15-20 20-25 25-30 30-38 38-45
Heating surface m2 1,36 1,65 2,15 2,65 3,2 3,95 4,63
Size of heated area m2 50-120 70-150 140-200 180-250 240-300 280-380 360-450
Thermal efficiency (optimal) % 79-84 79-84 79-84 79-84 79-84 79-84 79-84
The maximum allowable working pressure Mpa 0,15 0,15 0,15 0,15 0,15 0,15 0,15
Required string exhaust Pa 20 22 23 26 28 30 32
The recommended heating water c 55/90 55/90 55/90 55/90 55/90 55/90 55/90
chimney section cm2 220 250 280 300 300 320 320
chimney section cm x cm - - - - - - -
chimney section Ø mm - - - - - - -
Minimum height of chimney m 6 6 7 7 8 9 10
Dimensions of flue mm 160 160 180 180 180 180 180
Power V/Hz 230/50 230/50 230/50 230/50 230/50 230/50 230/50
diameter supply and return mm G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2" G 1 1/2"
boiler weight kg 210 260 287 318 355 380 410
Water storage capacity l 45 56 74 83 94 115 132
Capacity loading chamber l 38 43 58 75 82 112 138
height mm 1252 1330 1330 1330 1330 1420 1420
The height from the base to the axis of the flue mm 1030 1090 1090 1090 1090 1180 1180
length mm 720 760 810 860 950 950 950
width mm 440 440 490 540 540 580 660
Width of basket mm - - - - - - -
The depth of the combustion chamber mm 300 350 400 450 550 550 550

* The height of the boiler is given without a fan. If you mount the fan M PLUS M WPA 120 should be added to the dimension of 180 mm.

 

 

MCE reserves the right to change without notice technical parameters, dimensions and specifications of the goods offered. Contained on this website information does not constitute assurance within the meaning of Art. 4 paragraph. 3 and 4 of the Act of 27 July 2002 on special conditions of consumer sale and amending the Civil Code (the "Act"), and do not constitute a description of the goods within the meaning of Art. 4 paragraph. 2 of the Act. This website does not constitute an offer within the meaning of Art. 66 of the Civil Code.